Dell (Force10) WYMGJ Compatible 25GBASE-SR SFP28 for Dell PowerSwitch S5x00F-ON

Dell (Force10)
SFP28
25G
Duplex
100 m
WYMGJ  DELL Compatible 25ge 850nm Short Wavelength Sfp+ Transceiver

Dell (Force10) compatible WYMGJ - Key Features

  • Compatibility: Dell (Force10)
  • Media Type: Multi-Mode Fiber (MMF) -OM3/OM4/OM5
  • Fiber Count: Duplex
  • Connector: Double LC/UPC
  • Maximum Distance: 100 m
  • Guaranteed Link Budget: 5.3 dB
  • Tx Wavelength: 850 nm
  • Supported Data Rate: 8.5 Gbps - 25.78 Gbps
  • DDM/DOM: Supported
  • Forward Error Correction (FEC): Host FEC Supported
  • Temperature Range: Standard 0°-70°C

Dell (Force10) WYMGJ Price

Lead timeIn Stock - Ships Next Business Day
Standard recommended retail price ex VAT:
14.53
Choice of 0+
Telecoms & Integrators Globally

Dell (Force10) compatible WYMGJ Specifications

Form Factor
SFP28
Media Type
Multi-Mode Fiber (MMF) -OM3/OM4/OM5
Fiber Count
Duplex
Connector
Double LC/UPC
Maximum Distance
100 m
Guaranteed Link Budget
5.3 dB
TX Wavelength
850 nm
RX Wavelength
850 nm
Supported Data Rate
8.5 Gbps - 25.78 Gbps
Supported Ethernet Applications
10G Ethernet (10.31Gbps), 25G Ethernet (25.78Gbps)
DDM/DOM
Supported
Forward Error Correction (FEC)
Host FEC Supported
Transmitter Type
VSCEL Laser
Average Launch Power (Min) Each Lane
-5 dBm
Average Launch Power (Max) Each Lane
2.4 dBm
Extinction Ratio (Min)
3 dB
Receiver Type
PIN photodiode
Rx Wavelength Bandwidth
20 nm
Average Receiver Sensitivity (Min) Each Lane
-10.3 dBm
Average Receiver Sensitivity (Max) Each Lane
2.4 dBm
Receiver Overload
2.4 dBm
Temperature Range
Standard 0°-70°C
Storage Temperature
-40° to 85°C
Relative Humidity
5 to 85%
Power Consumption (Max)
0.3 W
Power
+3.3V single power supply
Compliance
SFF-8432, CE, Class 1 FDA and IEC60825-1 Laser Safety Compliant, RoHS, SFF-8431, SFF-8472, SFP28 MSA

Dell (Force10) compatible WYMGJ Datasheet

v3

Complete technical specifications and product details

Updated:Apr 7, 2026Format:PDF

Dell (Force10) compatible WYMGJ Description

EdgeOptic's WYMGJ compatible is a Dell (Force10)-coded 25GBASE-SR SFP28 transceiver built as a direct replacement for the Dell WYMGJ. It ships with Dell-recognized EEPROM vendor and part-number strings so Dell PowerSwitch S5x00F-ON series and PowerEdge platforms with 25G SFP28 interfaces identify the optic as a native Dell part. Link-up, receive-optical-signal and DOM telemetry surface through the host NOS on the standard optic-inventory path (OS10 Enterprise and SmartFabric OS10) without any vendor-override step.

Optical behavior is 25GBASE-SR per IEEE 802.3by Clause 112 over duplex multi-mode fiber: 100m on OM4, 70m on OM3. Line signaling rate is 25.78125 Gbd, single-rate, per IEEE 802.3by Clause 112. Transmit power is -8.4 to +2.4 dBm, receive sensitivity -10.3 dBm, link budget 5.3 dB per IEEE 802.3by Clause 112 Table 112-3 (RS-FEC per Clause 108 operates at the PCS layer and does not alter the optical power budget). Wavelength 850nm VCSEL, duplex LC/UPC, DOM per SFF-8472. Operating case temperature is 0 to 85 degrees Celsius (extended temperature range, EXT class per SFF MSA conventions), which differentiates WYMGJ from the standard 0 to 70 degrees Celsius Dell SFP28 SR ordering codes and suits deployments in racks with limited forced-air cooling and high-ambient indoor equipment rooms.

WYMGJ is a Dell ordering code for a 25GbE SFP28 SR short-reach module specified against Dell PowerSwitch data-center switches with 25G SFP28 interfaces. The primary in-scope platforms are the Dell PowerSwitch S5x00F-ON series (S5248F-ON with 48 x 25G SFP28 ports, S5212F-ON, S5232F-ON, S5224F-ON, S5296F-ON) and Dell PowerEdge servers with rNDC or OCP 25G SFP28 adapters. Dell is commonly referenced by resellers as cross-listing WYMGJ with the alternate ordering codes 407-BBZS and P7D7R for the same optical part; EdgeOptic's compatible targets the WYMGJ optical specification directly.

Dell's public position on optical compatibility for standard PowerSwitch platforms is that MSA-compliant 25G SFP28 modules operate on the host without a platform-side vendor-lock step. EdgeOptic's WYMGJ compatible carries the Dell EEPROM vendor and part-number strings that OS10 reads on optic insertion, so the module is identified as a native Dell optic on the standard OS10 inventory path. Operators running a locked optic profile on a specific PowerSwitch SKU can request the exact EEPROM vendor and PN strings from EdgeOptic for verification before deployment.

On FEC, 25G FEC mode is configured at the MAC layer on each link partner and the optical path is agnostic to the host FEC profile. RS-FEC per IEEE 802.3by Clause 108 is the default path for 25GBASE-SR on Dell PowerSwitch and is the mode WYMGJ is specified against; Clause 74 Fire Code FEC (BASE-R) and no-FEC operation are supported at the optical layer where both link partners are configured for that FEC profile. DOM registers for transmit power, receive power, supply voltage, laser bias current and module case temperature are accessible through standard SFF-8472 reads on the OS10 transceiver-diagnostics interface and on any EEPROM-aware link partner. Every unit is factory-tested to the 25GBASE-SR optical specification per IEEE 802.3by Clause 112 before dispatch.

For volume pricing, Dell EEPROM vendor and part-number strings for pre-deployment verification on a specific PowerSwitch S5x00F-ON SKU and OS10 build, or confirmation of the 0 to 85 degrees Celsius extended-temperature rating for a rack with limited cooling, contact our sales team and we will respond within one business day.

Frequently Asked Questions

Is the Dell WYMGJ rated for extended temperature environments?

Yes. Dell WYMGJ is the extended-temperature variant in the Dell 25GbE SFP28 SR ordering range, rated for a 0 to 85 degrees Celsius operating case temperature (the '85C' designation in Dell product listings). That is a 15-degree headroom above the standard 0 to 70 degrees Celsius commercial range and suits deployments in rack positions with limited forced-air cooling and high-ambient indoor equipment rooms. EdgeOptic's WYMGJ compatible is specified to the same 0 to 85 degrees Celsius case-temperature range as the Dell original.

Which Dell PowerSwitch platforms accept the WYMGJ 25G SFP28 module?

Dell specifies WYMGJ against the PowerSwitch S5x00F-ON data-center range with 25G SFP28 interfaces. The primary platforms in scope are S5248F-ON (48 x 25G SFP28 ports plus 4 x 100G QSFP28 uplinks), S5212F-ON, S5224F-ON, S5232F-ON and S5296F-ON, plus Dell PowerEdge servers with rNDC or OCP 25G SFP28 adapters. For confirmation against a specific PowerSwitch SKU and OS10 build, contact us for pre-deployment verification.

Is WYMGJ commonly cross-referenced with Dell 407-BBZS or P7D7R?

Yes, commonly. Dell resellers and secondary-market listings regularly cross-reference WYMGJ with 407-BBZS and P7D7R as alternate Dell ordering codes for the same 25GbE SFP28 SR 85C optical part. EdgeOptic's compatible is specified against the WYMGJ optical profile directly; buyers matching an existing Dell deployment on any of these three ordering codes are sourcing the same 25GBASE-SR 850nm SFP28 optical class.

Does the WYMGJ extended-temperature rating change the fiber-type or reach requirements?

No. WYMGJ is 25GBASE-SR per IEEE 802.3by Clause 112 over duplex multi-mode fiber (LC/UPC connectors), with 100m on OM4 and 70m on OM3, the same media envelope as the standard 0 to 70 degrees Celsius Dell SFP28 SR ordering codes. The 0 to 85 degrees Celsius extended-temperature rating affects the operating case temperature envelope, not the optical media or reach budget. OM5 is not listed in the 25GBASE-SR Clause 112 reach table; single-mode fiber is not supported on 25GBASE-SR.

How do I read DOM diagnostics for the WYMGJ on a Dell PowerSwitch running OS10?

DOM registers for transmit power, receive power, supply voltage, laser bias current and module case temperature are implemented per SFF-8472 Rev 12.0. On Dell PowerSwitch platforms, DOM values are exposed through the OS10 transceiver-diagnostics interface on the monitored 25G SFP28 port; the exact command depends on the OS10 build on the platform. The same SFF-8472 register surface is readable from the switch or NIC on the other end of the link, so DOM cross-checking from both sides is straightforward.