100G BiDi QSFP28 LR1 20km Transceiver (Side B): BIDI-100G-Q28-SL20B

QSFP28
100G
BiDi
20 km
1310 nm
100G BiDi QSFP28 LR1 20km Transceiver (Side A)

100G BiDi QSFP28 LR1 20km Transceiver (Side B) Overview

EdgeOptic's 100G BiDi QSFP28 LR1 20km Side B transceiver delivers single-fiber, single lambda BiDi connectivity (one dedicated wavelength per transmit/receive direction) for extended-reach 100 Gigabit Ethernet links. Operating at 1310nm transmit and 1291nm receive on a single LC/UPC connector, this module reaches up to 20km over single-mode fiber with a 9.8 dB average link budget at 106.25 Gbps PAM4. This Side B module must be paired with a Side A module (BIDI-100G-Q28-SL20A) for a working link; single-fiber BiDi pairs always combine one Side A and one Side B unit with complementary transmit and receive wavelengths.

  • Media Type: Single-Mode Fiber (SMF)
  • Connector: Single LC/UPC
  • Fiber Count: BiDi
  • Maximum Distance: 20 km
  • Average Link Budget: 9.8 dB
  • Tx Wavelength: 1310 nm
  • Supported Data Rate: 106.25 Gbps
  • DDM/DOM: Supported
  • Forward Error Correction (FEC): Integrated in DSP
  • Temperature Range: Standard 0°-70°C

100G BiDi QSFP28 LR1 20km Pricing

SKUSKU:BIDI-100G-Q28-SL20B
Lead timeIn Stock - Ships Next Business Day
Standard recommended retail price ex VAT:
290.64
Choice of 0+
Telecoms & Integrators Globally

100G BiDi QSFP28 LR1 20km Transceiver (Side B) Specification

Form Factor
QSFP28
Modulation
PAM4 (Pulse Amplitude Modulation 4-level)
Media Type
Single-Mode Fiber (SMF)
Connector
Single LC/UPC
Fiber Count
BiDi
Maximum Distance
20 km
Average Link Budget
9.8 dB
TX Wavelength
1310 nm
RX Wavelength
1291 nm
Supported Data Rate
106.25 Gbps
Supported Ethernet Applications
100G Ethernet PAM4 (106.25 Gbps)
DDM/DOM
Supported
Forward Error Correction (FEC)
Integrated in DSP
Transmitter Type
EML Laser
Tx Wave Bandwidth
20 nm
Average Launch Power (Min) Each Lane
-0.2 dBm
Average Launch Power (Max) Each Lane
6.6 dBm
Receiver Type
PIN photodiode
RX Wave Bandwidth
20 nm
Average Receiver Sensitivity (Min) Each Lane
-7.6 dBm
Receiver Overload
7.6 dBm
Temperature Range
Standard 0°-70°C
Storage Temperature
-40° to 85°C
Relative Humidity
5 to 85%
Power Consumption (Max)
4.5 W
Power
+3.3V single power supply
Compliance
CE, RoHS, IEEE 802.3cd, CAUI-4, SFF-8679

100G BiDi QSFP28 LR1 20km Transceiver (Side B) Datasheet

v3

Complete technical specifications and product details

Updated:Aug 5, 2026Format:PDF

100G BiDi QSFP28 LR1 20km Transceiver (Side B) Description

EdgeOptic's BIDI-100G-Q28-SL20B is a 100G BiDi QSFP28 module built on a single-fiber, single lambda BiDi design (one dedicated wavelength per transmit/receive direction, as opposed to multi-wavelength WDM BiDi variants), with 20km reach over single-mode fiber and a single LC/UPC connector. This quad small form-factor pluggable transceiver uses PAM4 line coding on one optical lane per direction, delivering 106.25 Gbps for 100 Gigabit Ethernet applications in metro network and data center interconnect deployments.

This Side B module transmits at 1310nm and receives at 1291nm on the same fiber strand, one dedicated wavelength per direction, the single lambda bidirectional pairing that lets one strand carry both directions of a 100G link on its two wavelengths. The transmitter is an EML laser and the receiver is a PIN photodiode, with integrated CDR to hold signal integrity at PAM4 data rates. FEC is integrated in the module's DSP, needed for PAM4 to detect and correct bit errors across the 20km link.

The module carries a 9.8 dB average optical link budget, which sets the maximum reach on a given fiber plant. Over standard single-mode fiber this supports links up to 20 kilometers, though actual reach depends on installed fiber attenuation, splice count, and connector losses on the specific route, so 20km is an indicative planning distance, not a fixed guarantee. This reach follows the 100G Lambda MSA's 100G-LR1-20 reach class convention for single lambda BiDi optics.

BIDI-100G-Q28-SL20B is a hot-pluggable QSFP28 module with a single LC/UPC optical connector. Its electrical interface conforms to IEEE 802.3cd, CAUI-4, and SFF-8679, so it works with standard QSFP28 host cages. The LR1 designation here refers to the 100G Lambda MSA reach class convention for 20km single lambda BiDi optics, not an IEEE-defined bidirectional PMD. IEEE 802.3cu's 100GBASE-LR1 clause covers a different, duplex two-fiber interface.

Digital diagnostic monitoring (DDM/DOM) reports transmitted and received optical power, module temperature, bias current, and supply voltage in real time. Integrated FEC inside the DSP corrects bit errors introduced across the fiber, which PAM4 signaling depends on for the extended 20km reach. The module operates from 0 to 70 degrees Celsius, draws a maximum of 4.5W at plus 3.3V, and stores between negative 40 and 85 degrees Celsius.

Compliance covers IEEE 802.3cd, CAUI-4, and SFF-8679 for the electrical interface, plus CE and RoHS certification.

BiDi transceivers must be deployed in matched pairs with wavelength-complementary transmit and receive plans. This Side B module transmits at 1310nm and receives at 1291nm, so it must connect to a Side A module, BIDI-100G-Q28-SL20A, built with a transmit of 1291nm and a receive of 1311nm on the same 20km link. Each receiver carries a 20nm RX wave bandwidth, so this Side B module's 1310nm transmit falls within the Side A receiver's passband, and Side A's 1291nm transmit falls within this Side B module's receiver passband. Two Side B modules will not link, since both transmit at 1310nm and listen near 1291nm. Pairing this 20km Side B module with a 10km Side A or Side B module will not work either, because the 10km pair runs its own wavelength plan. Order the matching 20km Side A module for this link.

Typical applications include metro network connections, data center interconnects, and campus backbone links where fiber conservation and 20km reach are both required.

The BIDI-100G-Q28-SL20B ships with a lifetime warranty. For project-quantity pricing or paired Side A ordering guidance, contact our sales team.

Frequently Asked Questions

Why does this Side B module need a Side A partner instead of a second Side B unit?

This Side B module transmits at 1310nm and receives at 1291nm. A second Side B unit on the far end also transmits at 1310nm and listens at 1291nm, so neither end has a receiver tuned near the wavelength the other end is sending on. The complementary Side A module, BIDI-100G-Q28-SL20A, transmits at 1291nm and receives at 1311nm. Each receiver carries a 20nm RX wave bandwidth, so this Side B module's 1310nm transmit falls within the Side A receiver's passband, and Side A's 1291nm transmit falls within this Side B module's receiver passband, making the two sides wavelength-complementary.

Can this 20km Side B module be paired with a 10km Side A or Side B module instead?

No. The 10km BiDi pair on this product line uses its own wavelength plan, separate from this 20km pair's 1310nm and 1291nm plan. Mixing a 20km Side B module with a 10km-rated partner leaves the transmit and receive wavelengths mismatched end to end, so the link will not establish. Order the matching 20km Side A module for this Side B unit.

How much fiber does a single-fiber BiDi link save compared with a duplex 100G LR4 link?

A BiDi pair carries both transmit and receive directions on one fiber strand per link, while a duplex LR4 link needs two strands, one for each direction. Over routes carrying many parallel 100G links, that difference cuts the fiber strand count needed per link in half.

What optical budget and reach should I plan for on this 20km single-fiber link?

The module carries a 9.8 dB average optical link budget, which is the figure to plan against. The 20km distance is an indicative planning number based on average attenuation and connector loss assumptions; actual reach on a specific route depends on that route's installed fiber attenuation, splice count, and connector losses, so verify the link budget against the real route before committing to a 20km deployment.